IRDye 680LT Donkey anti-Guinea Pig IgG Secondary Antibody

IRDye® 680LT Donkey anti-Guinea Pig IgG Secondary Antibody

IRDye 680LT Donkey anti-Guinea Pig IgG Secondary Antibody

Immunogen

Guinea Pig IgG, whole molecule

Purity and Specificity

Isolation of specific antibodies was accomplished by affinity chromatography using antigens immobilized on agarose beads. Based on immunoelectrophoresis and/or ELISA, the antibody reacts with whole molecule guinea pig IgG as well as the light chains common to other guinea pig immunoglobulins. No reactivity was detected against non-immunoglobulin serum proteins. This antibody has been tested by ELISA and/or solid-phase adsorbed to ensure minimal cross-reactivity with bovine, chicken, goat, Syrian hamster, horse, human, mouse, rabbit, rat, and sheep serum proteins. The conjugate has been specifically tested and qualified for Western blot applications.

Applications

Recommended for:

  • Western Blot
  • Protein Array
  • Immunohistochemistry
  • Microscopy
  • 2D Gel Detection
  • Tissue Section Imaging

Not Recommended for:

  • Small Animal Imaging
  • In-Cell Western Assay
  • On-Cell Western Assay

Formulation

IRDye 680LT Secondary Antibodies are supplied as purified immunoglobulin conjugates, lyophilized in phosphate-buffered saline, pH 7.4. Protect from light. Store at 4 °C prior to reconstitution.

Each vial contains 10 mg/mL BSA (free of IgG and protease) as a stabilizer and 0.01% sodium azide as a preservative, after reconstitution. Concentration is 1.0 mg/mL when reconstituted as directed. Refer to the pack insert for details on reconstitution.

Recommended Dilutions

Application Recommended Suggested Range
Odyssey® Western blot detection 1:20,000 1:10,000 - 1:50,000
Other User optimized

Optimum dilutions will vary and should be determined empirically.

RRID

  • P/N 925-68030: RRID AB_2814910
  • P/N 926-68030: RRID AB_10706310

Example Data

IRDye® 680LT Donkey anti-Guinea Pig IgG Secondary Antibody data
Detection of guinea pig IgG with IRDye 680LT Donkey anti-Guinea Pig. Serial dilutions of Guinea Pig IgG were spiked into C32 lysate (Santa Cruz P/N sc-2205). Samples were resolved on a 10% Bis-Tris gel and transferred to Odyssey® Nitrocellulose membrane (P/N 926-31092). The membrane was blocked with Odyssey Blocking Buffer (P/N 927-40000) followed by detection with IRDye 680LT Donkey anti-Guinea Pig (P/N 926-68030).

Selected P/N: 926-68030,925-68030