Operating Instructions
Table of Contents
The Basics
1 | System Description |
What it is, what it does, and how it does it
2 | Assembling the LI-6400XT |
Putting it all together
6400-01 CO2 Injector Installation
External Quantum Sensor Installation
Attaching the LED Light Source
6400-40 Leaf Chamber Fluorometer
3 | Guided Tours |
Learning how to make it work
Tour #2: New Measurement Mode Basics
Tour #3: Controlling Chamber Conditions
Tour #6: Configuration Introduction
4 | Making Measurements |
The fundamentals of good measurements
Useful Details
Chapter numbers given here correspond with chapter numbers in the v6.2 instruction manual. Chapters not listed below are in the instruction manual.
7 | Environmental Control |
How OPEN controls chamber conditions
Working with Files
Chapter numbers given here correspond with chapter numbers in the v6.2 instruction manual. Chapters not listed below are in the instruction manual.
11 | Connecting to a Computer |
Retrieving your data, and remote control
Maintenance & Troubleshooting
Chapter numbers given here correspond with chapter numbers in the v6.2 instruction manual. Chapters not listed below are in the instruction manual.
18 | Calibration Issues |
The difference between 'data' and good data
Zeroing the Leaf Temperature Thermocouple
6400-40 Leaf Chamber Fluorometer
19 | Maintenance and Service |
The care and feeding of your new pet
Servicing the External CO2 Source Assembly
20 | Troubleshooting |
When things go wrong
New Measurements Mode Warning Messages
Leaf Chamber Fluorometer
Chapter numbers given here correspond with chapter numbers in the v6.2 instruction manual. Chapters not listed below are in the instruction manual.
27 | Leaf Chamber Fluorometer |
Using the 6400-40 Leaf Chamber Fluorometer
Soil CO2 Flux Chamber
Instruction Manuals
(6400_Manual_Using the 6400XT_v6.2.pdf)
**CURRENT VERSION** Using the LI-6400/XT. Instruction manual for the LI-6400XT Portable Photosynthesis System, instruments running software version 6.2.x and above.
Using the LI-6400, Software version 5
(6400_Manual_Using the 6400XT_v5.3.pdf)
Instruction manul for the LI-6400 Portable Photosynthesis System, instruments running software version 5.3.
Using the LI-6400, Software version 4
(6400_Manual_Using the LI-6400_v4.pdf)
Instruction manual for the LI-6400 Portable Photosynthesis System, instruments running software version 4.
6400-09 Soil CO2 Flux Chamber instruction manual
Instruction manual for the 6400-09 Soil Respiration Chamber.
Utilizando o LI-6400/LI-6400XT Sistema portátilde fotossíntese
(6400XT_Manual_Portuguese_Translation.pdf)
Brazilian Portuguese translation of the LI-6400XT instruction manual.