Application Notes, Tech Tips, and Other Documents
Summary | ||
---|---|---|
NEW! Logging sun-induced fluorescence, reflectance, and vegetation indices in EC datasets | Instructions for using the JB Hyperspectral Devices RoX and FloX instruments with LI-COR eddy covariance systems. This enables you to log sun-induced fluorescence and reflectance parameters, as well as vegetation indices, in eddy covariance data sets. | application note |
NR Lite2 Net Radiometer Installation Guide | Instructions for using the NR Lite 2 in biomet sensor packages | install guide |
NR01 Net Radiometer Installation Guide | Instructions for using the Hukseflux NR01 net radiometer in biomet systems. | install guide |
CNR4 4-component Radiometer Installation Guide | Instructions or using the CNR4 in biomet packages. | install guide |
CNF4 Heater and Ventilation Unit for the CNR4 | Installation guide for the Kipp & Zonen CNF4 heater and ventilation unit accessory for the CNR4 | install guide |
LI-190R Quantum Sensor Installation Guide | Instructions for using the LI-190R in biomet sensor packages | install guide |
LI-200R Pyranometer Installation Guide | Instructions for using the LI-200R Pyranometer in biomet sensor packages. | install guide |
HMP-155 Humidity and Temperature Probe Installation Guide | Instructions for using the HMP155 in biomet sensor packages | install guide |
7900-180 LI-COR Soil Temperature Sensor Installation Guide | Instructions for using the 7900-180 soil temperature probe in biomet sensor packages. | install guide |
EC-5 Soil Moisture Probe Installation Guide | Instructions for using the EC-5 in the Basic biomet sensor package | install guide |
Stevens HydraProbe Installation Guide | Instructions for using the Stevens HydraProbe (SDI-12) in biomet sensor packages | install guide |
HFP01 Soil Heat Flux Plates Installation Guide | Instructions for using Soil Heat Flux Plates in biomet sensor packages | install guide |
HFP01SC Self-calibrating Soil Heat Flux Plates Installation Guide | Instructions for using Self-calibrating Soil Heat flux Plates in biomet sensor packages. | install guide |
TR-525M Rain Gauge Installation Guide | Instructions for using the Texas Electronics TR-525M rain gauge in biomet sensor packages. | install guide |
Using Campbell Scientific Dataloggers to Collect Biomet Data |
Document describing how to use the CR3000, CR1000, or CR6 to record biological and meteorological data in a LI-COR eddy covariance system. |
install guide |
AirLink RV-50/X Cellular Communication Manual (with LI-COR Data Acquisition System) | Instruction manual for cellular communication systems with the Sierra Wireless AirLink RV-50 wireless gateway in biomet systems that include the LI-COR Data Acquisition System. | manual |
AirLink LS300 Cellular Communication Manual | Instruction manual for cellular communication systems with the Sierra Wireless AirLink LS300 wireless gateway. | manual |
Heavy Duty Adjustable Tripod Instruction Manual |
Instruction manual for the Heavy Duty Adjustable Tripod. |
manual |
Satellite Communication for Eddy Covariance and Soil Gas Flux Systems | Instruction manual for satellite communication systems. | manual |
SmartFlux 2 System Instruction Manual | Instruction manual for the SmartFlux 2 System. | manual |
SunWize Solar Power Supplies Instruction Manual | Instruction manual for using SunWize solar power supplies with LI-COR equipment. | manual |
New tools for a comprehensive time- and space-synchronized flux, weather, and soil optical sensor networks | Poster presentation from the European Geophysical Union (2018) meeting that describes the integration of measurements across scales. | poster |
Data Acquisition Module Quick-start Guide | Quick-start guide with basic information about the Data Acquisition Module | quick-start guide |
Data Retention Module Quick-start Guide | Quick-start guide with basic information about the Data Retention Module | quick-start guide |
Using a Cradlepoint Modem with LI-COR Eddy Covariance Systems | This technical tip describes how to use a Cradlepoint modem to enable remote communications with LI-COR eddy covariance systems. | tech tip |
Solar power supply considerations | Describes how to determine the correct size of solar and battery power supply for an eddy covariance site. | tech tip |