Display

The Display panel allows you to edit the parameters that display the selected image in the image view. The Display panel has individual sections for each channel available on a given acquisition. This example shows the 700 channel in red and the 800 channel in green.

Features

Click the Features at the top left corner of the Display panel to toggle between displaying and hiding all features on the image. Features include Bands, Lanes, Wells, Spots, Annotations, and more. Select specific features to display or hide on the Show group in each Analysis tab.

Brightness and Contrast

You can adjust the display with the Brightness and Contrast sliders. Drag a slider to adjust the display.

Image Studio display panel

You can also adjust the display using curves on a histogram. Click Curves on the top of the Display panel to open the Curves tab.

You can also click the arrow (>) in the Display group on the Image tab to open a dialog and choose Curves to view the Curves for this image. Select Brightness/Contrast to view the Brightness and Contrast sliders again.

Curves

The x-axis of each panel represents the raw pixel values. Each panel has a bar graph displaying a histogram of number of pixels with each raw value. The higher the bar at a given location on the x-axis, the more pixels that contain that particular intensity value. This histogram is shaded with the color map in use for that channel. Also shown in each panel is an adjustable curve that maps raw data to displayed data.

Image Studio display panel

The adjustable curve overlaying each histogram represents how the raw data maps to the displayed data. Adjust any of the three dots on the line (Max, Min, or K Value) to optimize the displayed image.To view the numbers hover the mouse over one of the three dots in the line. The Max and Min numbers are displayed. The middle one also shows the K value, which is used to smoothly change between linear (K=0) and logarithmic (K=1) mappings of the data onto the color maps.

  • Moving the Max Point to the left is similar to increasing the Contrast value in the Odyssey software. As more of the intensity values are mapped to the brightest display values, the bands become brighter.
  • Moving the Min Point to the right shades more of the lower intensity values to lower display values, creating a visually cleaner background.
  • Increasing the K value reduces the contrast between the higher and lower intensity values, so less intense bands appear brighter while very bright bands are avoided.

Adjusting the Parameters

You can adjust each channel’s display parameters independently.

  • Image Studio 700 channel button Use the Channel label to cycle through channel views. Press once to show the single channel. Press again to show the other channels. 
  •  Image Studio 3 black icon Use the disable button to disable (gray out) the channel. This is necessary when you are adding shapes. 
  •  Image Studio color channel red icon Image Studio color channel green icon Image Studio color channel blue icon Image Studio pseudo color channel icon Use the color buttons to change the channel’s display color. 
  • Image Studio color channel gray Image Studio color channel white Use the gray scale buttons to display the channel in gray scale. This is useful for displaying the image for reports that will be published. 
  • Image Studio Zoom In iconImage Studio Zoom Out icon Use the zoom buttons to zoom in on the range of pixel values for the channel.
  • Image Studio Zoom to Fit icon Use the expand button to show the full histogram in full zoomed out view. Use the zoom in button to zoom back incrementally or the automatic button to zoom in all the way. 
  • Image Studio Pick Image icon Use the Choose Display button to select the best display from six choices. See Choose Display for more information.
  • Image Studio wizard icon Use the Adjust Display button to open a dialog to help you set the min and max points of the display mapping. See Adjust Display for more information.

The Choose Display and Adjust Display dialogs automatically open after a scan for each channel acquired. Click the arrow (>) in the Display group to open the Display Options dialog and remove the check marks to disable this feature.

Image Studio display options dialog

Link Image Display Values

Click Link at the top of the Display panel to force all images currently in the filtered Images Table to have the same Image Display values as those applied to the display of the selected image. When the Image Display values are linked, any changes that you make to the Curves or Brightness/Contrast sliders affect all the images in the filtered view regardless of the image view mode (single image or multi-image mode).

The Link button is only enabled after a filter has been defined and applied to the Images table. It is unavailable if no filter has been applied.

The Image Display values will differ depending on the instrument and acquisition settings used. Linking the Image Display values of images from different instruments, or from the same instrument with different acquisition settings, will not provide accurate comparisons.