Air Pumps and Accessories for LI-COR Gas Analyzers
|
Suggested parts and vendors for air pumps and other accessories needed to flush the sample cells of many LI-COR closed-path gas analyzers. |
application note |
Measuring pCO2 and Dissolved Inorganic Carbonates in Water
|
Application note that describes how to use LI-COR analyzers in systems that measure the partial pressure of CO2 (pCO2) and dissolved organic carbonates in water. |
application note |
Measuring Small Volumes of CO2 with the LI-7000
|
Application note about small volume CO2 measurements with the LI-7000. |
application note |
Communicating with LI-COR instruments using LabVIEW
|
Basic instructions that describe how to communicate with LI-COR instruments using LabVIEW. Includes sample programs to read data. |
application note |
The Importance of Water Vapor Measurements and Corrections
|
This application note describes how water vapor influences the measurement of carbon dioxide by infrared gas analysis in several ways, which can lead to significant measurement errors. |
application note |
Using CO2 and H2O Scrubbers with LI-COR Gas Analyzers
|
This application note describes the use of various chemicals used internally with LI-COR gas analyzers to keep absorbing gases out of internal spaces that are part of the optical path. |
application note |
Mylar Insulator Installation Kit
|
Installation Guide for the 7000-904 Mylar Insulator Kit. Insulates the keypad of the LI-7000. |
install guide |
Digital Board Upgrade Kit
|
Installation instructions for the 7000-902-1 Digital Board Upgrade Kit. |
install guide |
LI-7000 CO2/H2O Analyzer Instruction Manual
|
Instruction manual for the LI-7000 |
manual |
Using the Sable Systems DG-4 to set the H2O span for LI-COR gas analyzers
|
You can adjust the H2O span in many LI-COR gas analyzers with a dewpoint generated by the Sable Systems DG-4 Dewpoint Generator. This tech tip provides some details. |
tech tip |
USB Connection Issue on Windows 8
|
This technical tip describes how to fix a problem whereby the USB port does not function with the LI-7000 on computers using Windows 8. |
tech tip |
Effects of temperature and pressure on CO2 infrared absorption with special emphasis on problems resulting from operation at high flow rates
|
Article describing the effects of temperature and pressure on absorption of infrared energy by carbon dioxide. |
technical note |
Effects of Temperature, Pressure, and Water Vapor on Gas Phase Infrared Absorption by CO2
|
Article that describes the effects of temperature, pressure, and water vapor on absorption of infrared energy by carbon dioxide. |
technical note |