Using the Flash Analysis Application
|
Note describing how to compare and optimize flash data from the LI-6800, LI-600, and the LI-6400/XT. |
application note |
Measuring Canopy Gas Exchange
|
This note describes how to measure gas exchange at the canopy level with the LI-6400/XT. |
application note |
Modification of LI-6400/XT to Control Low CO2 Concentrations
|
This note describes how to control low CO2 concentrations in the LI-6400/XT. |
application note |
Interfacing Custom Chambers with the LI-6400/XT Sensor Head
|
This note describes how to interface custom chambers to the LI-6400/XT sensor head. |
application note |
Using the Whole Plant Arabidopsis Chamber
|
This note describes how to use the 6400-17 Whole Plant Arabidopsis Chamber with the LI-6400/XT, including installation tips and experimental validation. |
application note |
Using the RGB Light Source
|
This note describes how to use the 6400-18A RGB Light Source. |
application note |
Understanding and Correcting Diffusion Leaks in the Opaque Conifer Chamber and Clear Conifer Chamber
|
This application note describes ways to address diffusion leaks in the Clear Conifer Chamber and the Opaque Conifer Chamber. |
application note |
Estimating Light Absorptance in the Leaf Chamber Fluorometer Using an External Quantum Sensor
|
This note describes how to estimate light used for photosynthesis using the fluorometer and a light sensor. |
application note |
Battery Data Sheet
|
A data sheet for the LI-6400/XT and LI-8100A batteries |
data sheet |
6400-01 CO2 Source Assembly Installation
|
Instructions for installing the CO2 source assembly. |
install guide |
6400-02B LED Light Source installation instructions for the LI-6400/XT
|
Instructions for installing the 6400-02B LED Light Source onto the LI-6400/XT Portable Photosynthesis System. |
install guide |
6400-05 Conifer Chamber installation instructions
|
Instructions for installing the 6400-05 Conifer Chamber onto the LI-6400/XT Portable Photosynthesis System. |
install guide |
6400-06 PAM-2000 and 6400-10 MiniPam Adapter installation instructions
|
Instructions for installing the 6400-06 PAM-2000 and 6400-10 MiniPAM Adapters from Walz onto the LI-6400/XT Portable Photosynthesis System. |
install guide |
6400-07 Needle Chamber installation instructions
|
Instructions for installing the 6400-07 Needle Chamber onto the LI-6400/XT Portable Photosynthesis System. |
install guide |
6400-08 Standard Clear Chamber Bottom installation instructions
|
Instructions for installing the 6400-08 Clear Chamber Bottom onto the LI-6400/XT Portable Photosynthesis System. |
install guide |
6400-11 Narrow Leaf Chamber
|
Installation instructions for the LI-6400/XT narrow leaf chamber. |
install guide |
6400-12 Coprocesser Installation
|
Installation instructions for the coprocesser. |
install guide |
6400-13 Thermcouple Adapter
|
Installation instructions for the LI-6400/XT thermocouple adapter. |
install guide |
6400-14 Opti-Sciences Fluorescence Probe Adapter installation instructions
|
Instructions for installing the 6400-14 Opti-Sciences Probe Adapter onto the LI-6400/XT Portable Photosynthesis System. |
install guide |
6400-15 Arabidopsis Chamber Installation and Operational Instructions for the LI-6400/XT Portable Photosynthesis System
|
Installation instructions for the 6400-15 Arabidopsis Chamber, for use with the LI-6400/XT Portable Photosynthesis System. |
install guide |
6400-17 Whole Plant Arabidopsis Chamber installation and operational instructions
|
Instructions for installing the 6400-17 Whole Plant Arabidopsis Chamber onto the LI-6400/XT Portable Photosynthesis System. |
install guide |
6400-18 RGB Light Source installation and operational instructions
|
Instructions for installing the 6400-18 RGB Light Source onto the LI-6400/XT Portable Photosynthesis System. |
install guide |
6400-22 Opaque Conifer Chamber installation instructions
|
Instructions for installing the 6400-22 Opaque Conifer Chamber onto the LI-6400/XT Portable Photosynthesis System. |
install guide |
6400-24 Bryophyte Chamber installation and operational instructions
|
Instructions for installing the 6400-24 Bryophyte Chamber onto the LI-6400/XT Portable Photosynthesis System. |
install guide |
6400-34 Needle Holder Kit
|
The 6400-34 Needle Holder Kit can be used with LI-6400/XT leaf chambers to measure conifer needles. The needle holders can be used with the Needle chamber and Clear Bottom chamber. |
install guide |
6400-37 Thick Gasket Kit
|
Instructions for the LI-6400/XT thick gasket kit. |
install guide |
6400-88 Expanded Temperature Control Kit installation instructions
|
Instructions for installing the 6400-88 Expanded Temperature Kit onto the LI-6400/XT sensor head to expand the range of temperature control. |
install guide |
6400-89 Insect Respiration Chamber installation and operational instructions
|
Instructions for using the 6400-89 Insect Respiration Chamber with the LI-6400/XT Portable Photosynthesis System. |
install guide |
6400-903 Catch Rod Repair Kit installation instructions
|
Instructions for replacing the catch rod in the LI-6400/XT sensor head handle. |
install guide |
6400-904 Log Switch replacement instructions
|
Instructions for replacing the log switch on the LI-6400/XT sensor head handle. |
install guide |
6400-906 Memory Board upgrade
|
Instructions for replacing the 6400-906 Memory Board in the LI-6400/XT console. |
install guide |
6400-907 Air Pump Replacement Instructions
|
Instructions for replacing the air pump. |
install guide |
6400-915 Digital Board Upgrade
|
Instructions for replacing the digital board in the LI-6400/XT Portable Photosynthesis System. |
install guide |
6400-926 Digital Board Upgrade
|
Instructions for replacing the digital board in the LI-6400/XT Portable Photosynthesis System, converting the instrument to an LI-6400/XT. |
install guide |
6400-928 Flow Restrictor Field Kit installation instructions
|
Instructions for replacing the flow restrictor in the 6400-01 CO2 Injector. |
install guide |
9964-102 Air Passage Spacer
|
Installation instructions for the 9964-102 Air Passage Spacer, which is required on older instruments (serial numbers less than PPS-1961) to ensure a good seal on the sensor head bottom leaf chamber. |
install guide |
Air Pump Replacement Instructions
|
Instructions for replacing the 6400-931 air pump in the LI-6400/XT console. |
install guide |
CO2 Tank Connector Block
|
Installation instructions for the 9964-033 CO2 Tank Connector Block, for situations where a CO2 source of longer duration than can be provided by the CO2 mini-cartridges is needed. |
install guide |
Dark Adapting Clip Kit
|
Installation instructions for the LI-6400/XT dark adapting clip. |
install guide |
Mixing Fan Replacement Instructions
|
Instructions for replacing the LI-6400/XT Mixing Fan. |
install guide |
Propafilm Leaf Chamber Covering
|
Installation guide to replace the propafilm on the leaf chamber. |
install guide |
Sample Cell Outlet Manifold Kit
|
Installation instructions for the LI-6400/XT sample cell outlet kit. |
install guide |
Scrubber/Desiccant Tube Assembly Tubing Replacement instructions
|
Instructions for replacing the flow tubing (p/n 222-00302) in the scrubber and desiccant tube if it becomes pinched or clogged with debris. |
install guide |
CO2 Source Assembly Replacement
|
Instructions for installing the CO2 source assembly. |
install guide |
Using the 8100-664 Trace Gas Sampling Kit
|
Instructions for assembling the Trace Gas Sampling Kit for use with the LI-6400/XT. Measurement instructions are included in the full PDF app note. |
install guide |
Peltier Cooler Kit
|
Installation instructions for the Peltier cooler kit. |
install guide |
Thermocouple Adapter
|
Installation guide for the thermocouple adapter. |
install guide |
Using the LI-6400/XT, Instruction manual for OPEN software version 6.2.x
|
Instruction manual for the LI-6400/XT Portable Photosynthesis System, software version 6.2.x and above. |
manual |
Using the LI-6400/XT, Instruction manual for OPEN software version 5
|
Instruction manual for the LI-6400/XT Portable Photosynthesis System, software version 5.3. |
manual |
Using the LI-6400/XT, Instruction manual for OPEN software version 4
|
Instruction manual for the LI-6400/XT Portable Photosynthesis System, software version 4. |
manual |
Comparison of Two Systems for Measuring Soil CO2 Flux: The LI-6400/XT and LI-8100A
|
Poster describing differences between the LI-8100A and LI-6400/XT for measuring CO2 flux from soils. |
poster |
Correcting for Changes in O2 Concentration in the LI-6400/XT Photosynthesis System
|
Poster describing how to address changes in O2 concentrations. |
poster |
Determination of Maximal Chlorophyll Fluorescence Using a Multiphase Single Flash of Sub-Saturating Intensity
|
Poster describing multiphase flash to measure maximum fluorescence yield. |
poster |
Determination of Maximal Chlorophyll Fluorescence Using a Multiphase Single Flash of Sub-Saturating Intensity
|
Poster entitled "Determination of Maximal Chlorophyll Fluorescence Using a Multiphase Single Flash of Sub-Saturating Intensity". |
poster |
Measurements of Soil CO2 Flux
|
Poster describing how to measure soil CO2 flux with the LI-6400/XT system. |
poster |
Novel Red, Green, Blue LED Light Source and Whole Plant Arabidopsis Chamber to Asses Small Plants
|
Poster describing the red, green, and blue light source and whole-plant Arabidopsis chamber. |
poster |
Photosynthetic Assessment of Small Plants Using Red, Green, Blue LED Light Source and Whole Plant Arabidopsis Chamber
|
Poster describing the red, green, and blue light source and whole-plant Arabidopsis chamber. |
poster |
Soil CO2 Flux Measurements: Theory and Comparison Between the LI-6400/XT and LI-8100A
|
Poster describing differences between soil gas flux measurements made with the LI-8100 and LI-6400/XT. |
poster |
Effects of temperature and pressure on CO2 infrared absorption with special emphasis on problems resulting from operation at high flow rates
|
Article describing the effects of temperature and pressure on absorption of infrared energy by carbon dioxide. |
publication |
Effects of Temperature, Pressure, and Water Vapor on Gas Phase Infrared Absorption by CO2
|
Article that describes the effects of temperature, pressure, and water vapor on absorption of infrared energy by carbon dioxide. |
publication |
Using the Sable Systems DG-4 to set the H2O span for LI-COR gas analyzers
|
You can adjust the H2O span in many LI-COR gas analyzers with a dewpoint generated by the Sable Systems DG-4 Dewpoint Generator. This tech tip provides some details. |
tech tip |
Clearing Storage Space from the File System
|
If the file system gets too full, you may have trouble working with files. This tip presents some solutions to the problem. |
tech tip |
Downloading Data Using an RS-232 Serial Connection
|
This Tech Tip describes how to download data from the LI-6400/XT using serial a connection. |
tech tip |
Checking the Leaf Fan
|
There are several ways to test for a failed or stuck mixing fan. This tech tip goes through the steps of diagnosing fan issues. |
tech tip |
‘Drieing’ Your Drierite the ‘Rite’ Way For the LI-6400/XT Portable Photosynthesis System
|
This technical tip describes how to regenerate Drierite after it has been exhausted, for re-use with the scrubber tubes on the LI-6400/XT or other gas analyzers. |
tech tip |
Calculating Irregular Leaf Area with the LI-6400/XT
|
This technical tip describes how to calculate irregular leaf areas, when the leaf doesn't cover the entire leaf chamber aperture on the LI-6400/XT. |
tech tip |
Connecting a Soil Moisture Probe to the LI-6400/XT
|
This technical tip describes how to connect a Decagon EC-5 soil moisture probe to the LI-6400/XT Portable Photosynthesis System. |
tech tip |
Dealing with Large, Moist Samples
|
This technical tip describes how to deal with high humidities when measuring large, moist samples in the Bryophyte and/or Conifer chambers on the LI-6400/XT. |
tech tip |
Faster Field Measurements of Asat
|
This technical tip describes how to make faster field measurements of the light-saturated rate of net CO2 fixation under ambient conditions (Asat) with the LI-6400/XT. |
tech tip |
Leaf Chamber Gasket Replacement
|
This technical tip describes how to replace the leaf chamber gaskets on the LI-6400/XT sensor head. |
tech tip |
Align Small Blades of Grass or Needles
|
This Tech Tip describes how to align small blades of grass or needles and keep them in place in the LI-6400/XT standard leaf chamber. |
tech tip |
LI-6400/XT Shipping Recommendations
|
This Tech Tip describes how to package the LI-6400/XT for shipping. |
tech tip |
LI-6400/XT Swap Meet
|
This tech tip describes the LI-6400/XT components that can interchanged safely, as well as those that must be used together due to matching electronic components. |
tech tip |
Look Ma, No Wires!
|
This technical tip describes how to incorporate wireless network connectivity into the LI-6400/XT, using a wireless router. |
tech tip |
Making a Stand for the LI-6400/XT
|
This technical tip shows how you can make a simple wooden stand for your LI-6400/XT. Includes dimensions and example photos. |
tech tip |
Match Valve Mismatch
|
This technical tip describes how you can determine if the match valve on the LI-6400/XT sensor head is working properly. |
tech tip |
Replacing the LI-6400/XT Battery Connector
|
This technical tip describes how to replace the battery connector on the LI-6400/XT console. |
tech tip |
Setting the Height of the LI-6400/XT Thermocouple
|
This technical tip describes the proper positioning of the 6400-04 leaf temperature thermocouple in relation to the leaf chamber, for the LI-6400/XT Portable Photosynthesis System. |
tech tip |
Solving an Oily Problem
|
This technical tip describes how to use CO2 cartridges in the 6400-01 CO2 Injector that were not purchased from LI-COR. |
tech tip |
When Ambient H2O is not Leaf Chamber H2O
|
This technical tip describes how to maintain the proper relative humidity in the LI-6400/XT leaf chamber to allow the plant to compensate for the loss of humidity due to removal of the boundary layer. |
tech tip |
Wireless Connectivity with the LI-6400/XT
|
This technical tip describes how to incorporate wireless network connectivity into the LI-6400/XT using a wireless router. |
tech tip |
Where's my Serial Port?
|
This technical tip describes how to use a Serial-to-USB adapter to connect your computer to a LI-COR instrument, for those computers that lack a serial port. |
tech tip |
CO2 Cartridges for the LI-6400/XT and LI-6800
|
This technical tip describes the best CO2 cartridges to use and provides some tips for their use. |
tech tip |
Software for Fitting Photosynthetic CO2 or Light Response Curves
|
This tip lists some software that is commonly used for fitting CO2 and light response curves. |
tech tip |
Measuring Photorespiration with the LI-6400/XT System
|
This tip describes some important considerations for measuring photorespiration using the LI-6400/XT. |
tech tip |
Recomputing LI-6400/XT data sets
|
How to recompute measurements collected with older software versions |
tech tip |
Making one-sided measurements
|
This tip describes how to make measurements from one side of a leaf. |
tech tip |
Using external sensors with the LI-6400/XT
|
This technical note describes how to connect external sensors to the LI-6400/XT auxiliary connector. |
technical note |
Scrubbing Chemicals in LI-COR Gas Analyzers
|
Note describing a change in chemical scrubbers used in gas analyzers. |
technical note |
Comparing a the Effect of a CO2 Controller and Buffer Volumes when making Respiration Measurements
|
Technical note that describes the effect of a CO2 controller compared to buffer volumes of different sizes. |
technical note |