Chambers
Depending on the system you ordered, you may have one or more of the following chambers.
10 cm survey chamber
The 10 cm survey chamber (8100-102) includes the chamber, spares kit (part number 8100-621), replacement gasket kit (part number 8100- 622), and the 6000-09TC soil temperature probe.
Spares kit
Table 1‑1. The 10 cm chamber spares kit components.
10 cm Survey Chamber Spares Kit |
1 |
8100-621 |
Cable Ties |
10 |
218-08499 |
Bev-a-line Tubing (11'; 3.35 m) |
1 |
222-01824 |
Thumb Nut |
4 |
165-00140 |
10 cm Soil Collars |
6 |
6581-157 |
Gasket kit
Table 1‑2. The 10 cm chamber gasket kit components.
10 cm Survey Chamber Gasket Kit |
1 |
8100-622 |
Foam Seal Gaskets |
20 |
6560-229 |
Soil Collar Gaskets |
2 |
6581-065 |
Chamber Flange Gaskets |
2 |
6581-066 |
Manifold Gaskets |
2 |
6581-057 |
Chamber Gasket Trim (2.2'; 0.67 m) |
1 |
226-07390 |
Loctite Adhesive |
1 |
208-05786 |
10-32 x 1/2" screws |
4 |
122-00014 |
4-40 x 3/8" screws |
18 |
122-01578 |
8-32 x 1/2" screws |
4 |
122-04328 |
Bellows kit
The bellows kit is an optional accessory that can be purchased individually.
Table 1‑3. The bellows kit components.
LI-8100A Bellows Kit (optional) |
1 |
8100-623 |
Silicone Lubricant |
1 |
210-01958-1 |
10-32 x 1/2" screws with o-ring |
4 |
138-07470 |
Manifold Gasket |
1 |
6581-057 |
Bellows, 3" I.D. x 4.25" O.D. |
1 |
254-7219 |
20 cm survey chamber
The 20 cm survey chamber (8100-103) includes the chamber, spares kit (part number 8100-631), replacement gasket kit (part number 8100- 632), and the 6000-09TC soil temperature probe.
Spares kit
Table 1‑4. The 20 cm survey chamber spares kit components.
8100-103 Survey Chamber Spares Kit |
1 |
8100-631 |
Cable Ties |
10 |
218-08499 |
Bev-a-line Tubing (11'; 3.35 m) |
1 |
222-01824 |
Thumb Nut |
4 |
165-00140 |
20 cm Soil Collars |
6 |
6581-044 |
Gasket kit
Table 1‑5. The 20 cm survey chamber gasket kit components.
20 cm Survey Chamber Gasket Kit |
1 |
8100-632 |
Cap Nuts |
4 |
163-02618 |
Foam Seal Gaskets |
20 |
6581-107 |
Manifold Gaskets |
2 |
6581-057 |
Soil Collar Gaskets |
4 |
6581-108 |
Chamber Gasket Trim (6'; 1.8 m) |
1 |
224-07606 |
Loctite Adhesive |
1 |
208-05786 |
10-32 x 1/2" screws |
4 |
122-00014 |
4-40 x 3/4" screws |
2 |
158-07847 |
Flat washer, #10 |
4 |
167-00154 |
Bellows kit
The bellows kit is an optional accessory that can be purchased individually.
Table 1‑6. The bellows kit components.
LI-8100A Bellows Kit (optional) |
1 |
8100-623 |
Silicone Lubricant |
1 |
210-01958-1 |
10-32 x 1/2" screws with o-ring |
4 |
138-07470 |
Manifold Gasket |
1 |
6581-057 |
Bellows, 3" I.D. x 4.25" O.D. |
1 |
254-7219 |
Long-term chambers
The 8100-104 and 8100-104C long-term chamber include the chamber, spares kit (part number 8100-613), and a replacement gasket kit (part number 8100-612).
Chamber spares kit
Table 1‑7. The long-term chamber spares kit components.
8100-104/C Long-Term Chamber Spares Kit |
1 |
8100-613 |
Cable Ties |
9 |
218-08499 |
Urethane Tubing (6'; 1.8 m) |
1 |
222-00303 |
Thumb Nut |
4 |
165-00140 |
20 cm Soil Collars |
2 |
6581-044 |
Bumpers |
4 |
191-08069 |
Cap Plugs |
5 |
620-08297 |
Gasket kit
Table 1‑8. The long-term chamber gasket kit components.
8100-104/C Long-Term Chamber Gasket Kit |
1 |
8100-612 |
Loctite Adhesive |
1 |
208-05786 |
Collar Gasket |
2 |
6581-060 |
Chamber Gasket Trim (6'; 1.8 m) |
1 |
224-07606 |
6-32 x 3/8" screws |
4 |
122-00009 |
4-40 x 3/8" screws |
18 |
122-01578 |