Service Discontinuation Notice
The original LI-8100 Soil CO2 Flux System was discontinued in 2010 with the introduction of the LI-8100A. Due to parts obsolescence, it is no longer practical to offer repair services for the original LI-8100 Analyzer Control Unit. Therefore, we are implementing a service parts phase-out plan for the original LI-8100. Instruments are still eligible for routine factory recalibration, but repair service is no longer be available.
The LI-8100A, LI-8150 Multiplexer, and chambers including the 8100-102 10 cm Chamber, 8100-103 20 cm Chamber, and 8100-104/C Long-Term Chamber, will continue to have full services available for the foreseeable future.
Manuals
LI-8100 Automated Soil CO2 Flux System and LI-8150 Multiplexer Instruction Manual
Instruction manual for the LI-8100 and LI-8150 Automated Soil CO2 Flux System.
8100-203 and 8150-203 Soil Temperature Thermistors with the LI-8100
Instructions for entering calibration coefficients into a Palm PDA that is used to configure the LI-8100.
Software
Embedded
LI-8100 Instrument (Embedded) Software v3.0.1.
This is the LI-8100 instrument (Embedded) Software, version 3.0.1. This version is required for Palm users. When updating, be sure to update the Windows Application Software as well.
LI-8100 Instrument (Embedded) Software v2.0.0.
This is the LI-8100 instrument (embedded) software, version 2.0.0. This software is required for use with Palm mobile devices that are running V1.0.6 software. When updating, be sure to update the Windows Application Software as well.
Interface
LI-8100 Windows Application Software v3.0.1
For use with Windows-based PCs. Includes exclusive LI-8100 Data Analysis Software. When updating, be sure to update the instrument (embedded) software as well.
LI-8100 Windows Application Software v2.0.0
For use with Windows-based PCs. Version 2.0.0. When updating, be sure to update the instrument (embedded) software as well.
Additional software is available from the LI-8100A software downloads page.
Frequently Asked Questions
We have examined many different USB adapters and found the type that we sell to work best with all of our instruments. Other adapters may work, but they may not.
We can only guarantee the FTDI adapter that we sell. It is included with many of the LI-COR instruments that require serial communication with a computer. We have found that some third-party USB adapters (Prolific, for example) do not accurately transmit all the data from the instrument to the computer, or vice versa. You should use an adapter with an FTDI chipset, and Belkin and Keyspan adapters typically work well with our instruments too.
All Documents
Summary | ||
---|---|---|
8100-908 Long-Term Chamber Thermistor Upgrade and Replacement Instructions | Installation guide for the 8100-908 long-term chamber thermistor. | install guide |
Vane Pump Replacement Instructions | Instructions for replacing the rotary vane pump (p/n 8100-929) in the LI-8100 Analyzer Control Unit. | install guide |
Source, Detector, and Optical Path Replacement Instructions | Instructions for replacing the source, detector, and optical path in the LI-800, LI-820, LI-840, and LI-8100A gas analyzers. | install guide |
Installing a network adapter to enable communication with LI-COR Trace Gas Analyzers. | Describes how to install a network adapter inside the original LI-8100 to enable network communication. this procedure makes it possible to connect a LI-COR Trace Gas Analyzer to the original LI-8100 system | install guide |
Configuring PDAs for use with the LI-8100A | Instructions for using an HP PDA with the LI-8100 Automated Soil CO2 Flux System. | manual |
Configuring the Palm LifeDrive for use with the LI-8100 | Instructions for using the Palm LifeDrive PDA with the LI-8100 Automated Soil CO2 Flux System. | manual |
Configuring the Palm Tungsten C for use with the LI-8100 | Instruction manual for using the Palm Tungsten C PDA with the LI-8100 Automated Soil CO2 Flux System. | manual |
Configuring the Palm TX for use with the LI-8100 | Instruction manual for using the Palm TX PDA with the LI-8100 Automated Soil CO2 Flux System. | manual |
Using the Sable Systems DG-4 to set the H2O span for LI-COR gas analyzers | You can adjust the H2O span in many LI-COR gas analyzers with a dewpoint generated by the Sable Systems DG-4 Dewpoint Generator. This tech tip provides some details. | tech tip |
Soil Moisture Probe Converter Spreadsheet | Spreadsheet to convert soil moisture probe output to volumetric water content values. | tech tip |
Using a Serial-to-USB Adapter with the LI-8100 | This document describes how to use a USB-to-Serial adapter to connect the LI-8100 to a computer that does not have a serial port. | tech tip |
Instructions for using the CalAdjust application | Instructions for using the CalAdjust application in older LI-820s, LI-840s, and LI-8100s. Not for new LI-820s, LI-840As, or LI-8100As. | technical note |
Temporary Fix for a Bad Source | Tech Tip describing a temporary fix for a bad optical source. | tech tip |