All Documents
Summary | ||
---|---|---|
Using the Smart Chamber with two TGAs | This note describes how to use two LI-COR trace gas analyzers with the Smart Chamber. | application note |
Monitoring and downloading data from your Trace Gas Analyzer remotely | An overview of settings used to remotely monitor and download data from a Trace Gas Analyzer | application note |
Using the LI-Integrator app | The LI-Integrator app is a simple Windows application that can compute area under the curve with data from LI-COR analyzers, including the LI-8xx series and LI-78xx series analyzers. | application note |
Using LI-COR Trace Gas Analyzers in multi-point sampling applications | This application note describes how to use the LI-7810 and LI-7815 Trace Gas Analyzers in tower applications and with valve switching systems. | application note |
Mobile measurement of fugitive gas emissions | Application note describing techniques to collect and visualize methane concentration data associated with either multiple fixed locations or while walking/driving | application note |
Integrating a LI-COR Trace Gas Analyzer with an LI-8100A/LI-8150 System | This application note describes how to integrate an LI-7810 into a LI-8100A Automated Soil CO2 Flux System. | application note |
Measuring gas concentrations of small air samples with LI-COR Trace Gas Analyzers | This application note describes how to determine the CH4, CO2, or N2O gas concentration in small samples. | application note |
Replacing the pump | Instructions for installing a replacement pump in the LI-78xx series Trace Gas Analyzers | install guide |
LI-7815 CO2/H2O Trace Gas Analyzer Instruction Manual | Instruction manual for the LI-7815. | manual |
Development of Novel Trace Methane and Trace Carbon Dioxide Analyzers—Performance Evaluation Studies and Results of Field Deployment | Poster that describes field and laboratory performance of the LI-7810 and LI-7815 Trace Gas Analyzers | poster |
New High-Precision Low-Power CO2and CH4 Analyzers for Multiple Applications | Poster presented at the European Geophysical Union (EGU) 2019 meeting | poster |
Performance validation of new high precision CH4 and CO2 analyzers based on optical feedback cavity enhanced absorption spectroscopy | Poster describing the performance characteristics of the LI-7810 and LI-7815 gas analyzers. | poster |
Measuring CH4 and CO2 with new generation High-Precision Low-Power Low-Maintenance Closed-Path Analyzers: Lab and Field Results | This report describes field and lab performance results for the LI-7810 and LI-7815 gas analyzers. | poster |
Avoiding water ingress in Trace Gas Analyzers | This note describes several ways to prevent drawing water into the trace gas analyzer air inlet. | technical note |
NEW! Using the reduced flow rate kit 7800-113 | Describes how to install the reduced flow rate kit, which can reduce the nominal flow rate from 250 sccm to about 70 sccm (firmware versions 2.0.25 and newer). | technical note |
Using the reduced flow rate kit 7800-112 (discontinued) | Describes how to install the reduced flow rate kit, which can reduce the nominal flow rate from 250 sccm to about 70 sccm (firmware versions 2.3.8 and older). | technical note |
Dealing with Daylight Saving Time | This tip advises on the use of daylight saving time with LI-COR products. | tech tip |
Specifications Sheet | Performance specifications for the analyzer | specs sheet |