References
Note: References are linked to the original publication when possible.
1 | Arya, S. P. 1998. Introduction to Micrometeorology. San Diego, Academic Press. |
3 | Billesbach, D. 2011. Estimating uncertainties in individual eddy covariance flux measurements: A comparison of methods and a proposed new method. Agricultural and Forest Meteorology, 151: 394-405. |
6 | Campbell, G. S. and J. M. Norman. 1998. Introduction to Environmental Biophysics. New York, Springer Science. |
7 | De Ligne, A. B. Heinesch, and M. Aubinet. 2010. New Transfer Functions for Correcting Turbulent Water Vapour Fluxes. Boundary-Layer Meteorology, 137: 205-221. |
9 | Finkelstein, P. L., and P. F. Sims. 2001. Sampling error in eddy correlation flux measurements. Journal of Geophysical Research, 106: 3503-3509. |
11 | Foken, T. and B. Wichura. 1996. Tools for quality assessment of surface-based flux measurements. Agricultural and Forest Meteorology, 78: 83-105. |
14 | Gash, J. H. C. 1986. A note on estimating the effect of a limited fetch on micrometeorological evaporation measurements. Boundary-Layer Meteorology, 35: 409-413. |
15 | Gash, J. H. C. and A. D. Culf. 1996. Applying linear de-trend to eddy correlation data in real time. Boundary-Layer Meteorology, 79: 301-306. |
16 | Göckede, M, T. Markkanen, B. H. Charlotte, T. Foken. 2006. Update of a footprint-based approach for the characterisation of complex measurement sites, Boundary-Layer Meteorology, 118: 635–655. |
18 | Grelle, A. and G. Burba. 2007. Fine-wire thermometer to correct CO2 fluxes by open-path analyzers for artificial density fluctuations. Agricultural and Forest Meteorology, 147: 48-57. |
20 | Horst, T. W. 1997. A simple formula for attenuation of eddy fluxes measured with first-order-response scalar sensors. Boundary-Layer Meteorology, 82: 219-233. |
21 | Horst, T. W. and D. H. Lenschow. 2009. Attenuation of scalar fluxes measured with spatially-displaced sensors. Boundary-Layer Meteorology, 130: 275-300. |
25 | Jackson, P. S. 1981. On the displacement height in the logarithmic velocity profile. Journal of Fluid Mechanics, 11: 15-25. |
27 | Kormann, R. and F. X. Meixner. 2001. An analytical footprint model for nonneutral stratification. Boundary-Layer Meteoroogy, 99:207–224. |
28 | Kaimal, J. C., J. C. Wyngaard, Y. lzumi, and O. R. Coté. 1972. Spectral characteristics of surface-layer turbulence. Quarterly Journal of the Royal Meteorological Society, 98: 563-589. |
29 | Kaimal J.C. and L. Kristensen. 1991. Time series tapering for short data samples, Boundary-Layer Meteorology, 57: 187-194. |
30 | Kljun, N., P. Calanca, M. W. Rotach, and H. P. Schmid. 2004. A simple parameterisation for flux footprint predictions. Boundary-Layer Meteorology, 112: 503-523. |
33 | Liu, H., G. Peters, and T. Foken. 2001. New equations for sonic temperature variance and buoyancy heat flux with an omnidirectional sonic anemometer, Boundary-Layer Meteorology, 100: 459-468. |
35 | Mann, J. and D. H. Lenschow. 1994. Errors in airborne flux measurements. Journal of Geophysical Research, 99: 519-526. |
36 | Massman, W. J. 1991. The attenuation of concentration fluctuations in turbulent flow through a tube. Journal of Geophysical Research, 96: 15269-15273. |
37 | Massman, W. J. 2000. A simple method for estimating frequency response corrections for eddy covariance systems. Agricultural and Forest Meteorology, 104: 185-198. |
38 | Massman, W. J. 2001. Reply to comment by Rannik on "A simple method for estimating frequency response corrections for eddy covariance systems." Agricultural and Forest Meteorology, 107: 247-251. |
40 | Mauder M. 2013. A comment on "How well can we measure the vertical wind speed? Implications for fluxes of energy and mass" by Kochendorfer et al. Boundary-Layer Meteorology 147: 329-335. |
42 | Mauder, M. and T. Foken. 2006. Impact of post-field data processing on eddy covariance flux estimates and energy balance closure. Meteorologische Zeitschrift, 15: 597-609. |
44 | McMillen, R. T. 1988. An eddy correlation technique with extended applicability to non-simple terrain. Boundary-Layer Meteorology, 43: 231-245. |
47 | Moore, C. J. 1986. Frequency response corrections for eddy correlation systems. Boundary-Layer Meteorology, 37: 17-35. |
48 | Nakai, T., M. K. van der Molen, J. H. C. Gash, and Y. Kodama. 2006. Correction of sonic anemometer angle of attack errors. Agricultural and Forest Meteorology, 136: 19-30. |
49 | Nakai, T., K. Shimoyama. 2012. Ultrasonic anemometer angle of attack errors under turbulent conditions. Agricultural and Forest Meteorology, 18: 162-163. |
50 | Rannik, Ü. and T. Vesala. 1999. Autoregressive filtering versus linear detrending in estimation of fluxes by the eddy covariance method. Boundary-Layer Meteorology, 91: 258-280. |
51 | Runkle, B. K., C. Wille, M. Gažovič and L. Kutzbach. 2012. Attenuation Correction Procedures for Water Vapour Fluxes from Closed-Path Eddy-Covariance Systems. Boundary-Layer Meteorology, 142:1-23. |
52 | Schotanus, P., F. Nieuwstadt, and H. de Bruin. 1983. Temperature measurement with a sonic anemometer and its application to heat and moisture fluxes, Boundary-Layer Meteorology, 26:81–93. |
53 | Smith, S. W. 1997. The scientist and engineer's guide to digital signal processing. USA: California Technical Publishing. |
54 | Stull, R. B. 1988. An Introduction to Boundary-Layer Meteorology. Dordrecht, The Netherlands: Kluwer Academic. |
57 | van Dijk, A., W. Kohsiek, H. de Bruin. 2003. Oxygen Sensitivity of Krypton and Lyman-α Hygrometers, Journal of Atmospheric and Oceanic Technology, 20, pp. 143-151. |
59 | Vickers, D. and L. Mahrt. 1997. Quality control and flux sampling problems for tower and aircraft data. Journal of Atmospheric and Oceanic Technology, 14: 512-526. |
61 | Wilczak, J. M., S. P. Oncley, and S. A. Stage. 2001. Sonic anemometer tilt correction algorithms. Boundary-Layer Meteorology, 99: 127-150. |
62 | WindMaster and WindMaster Pro User Manual, Issue 5 1561-PS-0001. 2009. Gill Instruments. |