PRODUCT
|
DESCRIPTION |
| |
LI-8100 Automated
Soil CO2 Flux System
A dedicated and complete system for automated, continuous, unattended long term,
and rapid, easy-to-make survey soil CO2 flux measurements.
Download Brochure
06.06.08 7282k |
|
LI-7500 Open
Path CO2/H2O
Gas Analyzer
An innovative, high speed, high precision, low
power consumption, open path CO2/H2O
gas analyzer that accurately measures absolute densities
of carbon dioxide and water vapor of turbulent
air structures.
Download
Brochure 06.06.08 1024k |
|
LI-7000 CO2/H2O
Gas Analyzer
A closed path CO2/H2O
gas analyzer featuring high sensitivity, outstanding
resolution and user- cleanable optics. Choice of
analog, RS-232, and USB data outputs.
Download
Brochure 06.06.08 2472k |
|
NEW! LI-6400XT Portable
Gas Exchange and Fluorescence System
The state-of-the-art system to measure photosynthesis,
fluorescence and soil CO2 flux.
When used with the Leaf Chamber Fluorometer, exchange
and fluorescence can be measured simultaneously
over the same leaf area.
New features include an
expansion slot that supports compact flash memory
cards, or an Ethernet connector. New 400 MHz processor
on the new digital board and new OPEN 6.0 software.
Download
Brochure
06.06.08 1155k |
|
LI-6262 CO2/H2O
Gas Analyzer
Features a dual detector system
to provide simultaneous measurements for both CO2 and
H2O using the same
optical path.
|
|
It provides a rapid, easy-to-use system for precise
measurements of both large and small objects.
Download
Brochure
06.06.08 676k |
|
LI-3000C Portable
Area Meter
For easy and rapid, non-destructive
leaf area measurements in the field.
|
|
LAI-2000 Plant
Canopy Analyzer
Uses an innovative technique for making rapid,
non-destructive measurements of leaf area index (LAI)
and other plant canopy structure attributes such
as Mean Tip Angle (MTA).
Download
Brochure
06.06.08 4098k |
|
Ergonomic and easy to use. Combines simple operation
and compact size with the ability to connect up
to ten sensors.
Download
Brochure
06.06.08 971k |
|
LI-840 CO2/H2O
Gas Analyzer
A low cost, low maintenance, low power consumption,
compact CO2/H2O
gas analyzer. It features multiple data outputs,
high and low alarms and user-cleanable optics. Designed
for continuous monitoring, it offers multiple data
output options including RS-232, analog, XML comm
protocol.
Download
Brochure
06.06.08 153k |
|
LI-820 CO2 Gas
Analyzer
The LI-820 CO2 Analyzer
is a low cost, low maintenance CO2 analyzer
for applications related to ambient CO2 measurement.
Download
Brochure
06.06.08 1150k |
|
LI-610 Portable
Dew Point Generator
A rugged, portable instrument that provides a
stream of gas with a precisely controlled dew point.
Most commonly used to perform user calibrations
on H20 channels of LI-COR CO2/H2O Analyzers.
Download
Brochure
06.06.08 914k |
| |
A single-channel readout device for use with any
of LI-COR's terrestrial light sensors.
Download
Brochure
06.06.08 441k |
|
LI-210 Photometric
Sensor
For interior and industrial lighting studies or
other illuminance applications.
Download
Brochure
06.06.08 581k |
|
For measuring global solar radiation. Used in
agricultural, meteorological, and solar energy
studies.
Download
Brochure
06.06.08 459k |
|
LI-193 Spherical
Underwater Quantum Sensor
Measures the photosynthetic photon flux density
(PPFD) in the 400-700 nm region at depths up to 350
meters.
Download
Brochure
06.06.08 1402k |
|
LI-192 Underwater
Quantum Sensor
Measures the photosynthetic photon flux fluence
rate (PPFFR) 400-700 nm region at depths up to
560 meters and pressures to 800 psi.
Download
Brochure
06.06.08 1402k |
|
LI-191 Line
Quantum Sensor
Measures the photosynthetic photon flux density
(PPFD) in the 400-700 nm region along a 1-meter length.
Download
Brochure
06.06.08 1453k |
|
LI-190 Quantum
Sensor
Spatially averages the photosynthetic photon flux density
(PPFD) in the 400-700 nm region.
Download
Brochure
06.06.08 1264k |