Protein Array Analysis

For LI-COR Infrared Imaging Systems

protein analysis

LI-COR now offers slide prep accessories and add-on software for protein array analysis on the Odyssey® Infrared Imaging System.

For tips on detecting the Panorama Mouse/Rat Tissue Extract Protein Array on the Odyssey System, download the protocol here.


Quantitative Fluorescence Imaging Analysis for Cancer Biomarker Discovery: Application to B-Catenin in Archived Prostate Specimens (Huang, et. al.)

Current Research featuring Protein Array Analysis and data from LI-COR Systems- for a list of papers click here.


Glass Slide Microarrayer

A simple and flexible system to make your own protein microarrays without major setup hassles or costs. This system provides you:

  • Convenience—print your own microarrays from 96-well plates.
  • Versatility—spot your samples as duplicates, triplicates or more.
  • Enhanced Features—print up to 768 spots per array. Print duplicate slides at the same time.
  • Spot Size—500 microns in diameter.
  • Spot Pitch—1,235 micron on horizontal axis and 750 microns on the vertical axis. You can change pitch easily by skipping rows or columns.
  
 

Array-Pro® Analyzer 4.5 Software

  • Odyssey images are easily imported for data analysis
  • Automatic grid, subgrid and spot finding overcome tedious spot template assignment
  • Reproducible results
  • Extensive background and signal options to optimize results
  • Characterize more precisely through grouping by cells, grids, and images
  • Statistical feedback helps determine experiment quality
IMG_4918.tif

Nitrocellulose Slides (25 per pack)

Nitrocellulose coated slides offer a greater binding capacity than other matrices for protein array applications. Coupled with infrared detection, the background fluorescence is significantly decreased, resulting in a higher signal to noise than traditional fluorescent detection methods.    go Order Now: LI-COR part number 926-30052.

IMG_4908.tif

Glass Slide Arrayer Replicator

Features two rows of 4 pins on 9mm centers for 96-well microplates. Used in conjunction with the Glass Slide Indexing System, 768 spots (~500 microns each) are placed onto a grid 18 mm wide and 36 mm tall on two separate slides. You can use as few spots as your samples require.    go Order Now: LI-COR part number 926-30062.

IMG_4916.tif

Glass Slide Indexing System

Unique spring loaded locating feature stabilizes either 1" x 3" or 25 mm x 75 mm glass slides 1 mm thick. The spring-loaded locator will hold irregular slides up to 25.9 mm (1.02") wide and 76.36 mm (3.007") long. Thinner or thicker slides can also be accommodated.    go Order Now: LI-COR part number 926-30060.

IMG_4902.tif

Microplate Indexing System

Registers Replicator pins to the center of microplate wells for consistent diameter spots. The indexing system helps keep track of source plate position and allows more uniform sample acquisition.    go Order Now: LI-COR part number 926-30064.

IMG_4920.tif

Wash and Blot Station

Washes and cleans Replicator pins between spotting.    go Order Now: LI-COR part number 926-30066.

Not Pictured: Lint Free Blot Paper PN 926-30068; Pin Cleaning Solution PN 926-30070;
Replacement Pins PN 926-30072

Array-Pro Screengrab.tif

Array-Pro® Analyzer 4.5 Software

Array-Pro Analyzer 4.5 sets a new standard for automation of spot identification. A patented grid overlay to define the spots of interest takes advantage of the inherent periodicity of spot placement. The benefit is the ability to reproduce exactly the same results of analysis from user to user. Through computer algorithm automation results are absolutely repeatable.    go Order Now: LI-COR part number 926-30050.

Shipping information: U.S.A.: Same-day shipping (Federal Express overnight) available on orders received before 12:00 noon CST. Canada: Allow 3-5 days for shipments. Germany & UK: Contact LI-COR GmbH. International: Contact a LI-COR distributor in your area. All shipments subject to availability.

x
A A A
line
800 | 1024 | max
Biotechnology
4647 Superior St
Lincoln, NE 68504
Toll-Free: 800-645-4267
Email: biohelp@licor.com
Environmental
4421 Superior Street
Lincoln, NE 68504
Toll-Free: 800-447-3576
Email: envsales@licor.com